Not be removed or the receptor window is scratched, contact the nearest Konica Minolta authorized service facility. In cases of malfunction, do not disassemble the CL-200A or attempt to repair it yourself. Contact the nearest Konica Minolta-authorized service facility. How to Store. Konica Minolta TN-514K TN-514C TN-514 TN-514Y Bizhub C458 C558 C658 Toner Cartridge Set (Black Cyan Magenta Yellow, 4-Pack) in Retail Packaging. $200.00 $ 200. Illuminance Color Meters from Konica Minolta measure photometric brightness and also provide detailed color information for light readings. CL-500A Illuminance Spectrophotometer The CL-500A is a lightweight, compact illuminance spectrophotometer used for the evaluation of high-class, next-generation lamps such as LED and EL illumination. Konica Minolta Honored By The Cannata Report Earns Three Frank Awards Including Best Marketing Strategy, Best Production Print Manufacturer And Best Female Executive 2019.11.6 Konica Minolta Partners With The National Kidney Foundation For NYC Kidney Walk President and CEO Rick Taylor to Co-chair 18th Annual Event.
Konica minolta cl-200a Is Similar To: CA-210 Konica Minolta (40.4% similar) This device has a luminance measuring range starting at cd m2. This device can measure distances as short as 20 40mm making it ideal for compact systems. Konica Minolta Sensing enjoy an unparalleled reputation for the reliability and longevity of their instruments. However, continual development in component technology means that eventually it is not possible to continue to support and maintain older instruments.
Konica Minolta Sensing enjoy an unparalleled reputation for the reliability and longevity of their instruments. However, continual development in component technology means that eventually it is not possible to continue
to support and maintain older instruments.
Because of this Konica Minolta Sensing Inc. are announcing the discontinuation of technical support for calibration- and repair services for the following instrument models.
The list below shows the items concerned as well as the recommended replacement model.
Model | Type | Year of introduction | Recommended Successor Model |
---|---|---|---|
CM-3700d | Spectrophotometer | 1994 | CM-3700A |
CM-3600d | Spectrophotometer | 1997 | CM-3600A |
CM-3610d | Spectrophotometer | 1998 | CM-3610A |
CM-3500d | Spectrophotometer | 1996 | CM-5 |
CM-3800d | Spectro-Fluorimeter | 1998 | -- |
CM-1000 | Box type Spectrophotometer | 1987 | |
CM-1000RH | Box type Spectrophotometer | 1989 | |
CM-2002 | Portable Spectrophotometer | 1991 | |
CM-2022 | Portable Spectrophotometer Kioti service manual free download 3054. | 1992 | |
CM-3200d | Box type Spectrophotometer | 1995 | |
CM-3300d | Spectrophotometer | 1998 | |
CM-503c | Portable Spectrophotometer | 1994 | CM-2500c |
CM-503d | Portable Spectrophotometer | 1997 | |
CM-503i | Portable Spectrophotometer | 1993 | |
CM-508c | Portable Spectrophotometer | 1994 | CM-2500c |
CM-508d | Portable Spectrophotometer | 1993 | |
CM-508i | Portable Spectrophotometer | 1993 | |
CM-525i | Portable Spectrophotometer | 1994 | |
CM-512m1 | Portable Spectrophotometer | 1994 | |
CM-512m2 | Portable Spectrophotometer | ||
CM-512m3 | Portable Spectrophotometer | 1997 | CM-M6 |
CR-15 (CECF-6) | Color Reader | 1997 | -- |
CECF-9 | Color Reader | 1997 | -- |
CR-200 | Chroma-Meter | 1986 | |
CR-200b | Chroma-Meter | 1986 | |
CR-210 | Chroma-Meter | 1986 | |
CR-210b | Chroma-Meter | 1986 | |
CR-221 | Chroma-Meter | 1987 | CM-2500c |
CR-231 | Chroma-Meter | 1990 | CM-2500c |
CR-241 | Chroma-Meter | 1989 | -- |
CR-300 | Chroma-Meter | 1990 | |
CR-310 | Chroma-Meter | 1990 | |
CR-321 | Chroma-Meter | 1991 | CM-2500c |
CR-331 | Chroma-Meter | 1990 | CM-2500c |
CR-331c | Chroma-Meter | 1991 | CM-2500c |
CR-354 | Chroma-Meter Tri-View | 1992 | -- |
CT-100 | Chroma-Meter | 1985 | CM-5 |
CT-210 | Chroma-Meter | 1986 | CM-5 |
CT-310 | Chroma-Meter | 1991 | CM-5 |
CT-320 | Chroma-Meter | 1992 | CM-5 |
CF-1 | Power Supply | 1989 | -- |
CF-101 | Online Color Sensor | 1989 | -- |
CF-131 | Online Color Sensor | 1993 | -- |
CF-1440 | Online Color Sensor | 1997 | -- |
GM-060 | Gloss Meter | 1988 |
Model | Type | Year of introduction | Recommended Successor Model |
---|---|---|---|
CA-310 | Display Colour Analyzer | 2010 | CA-410 |
CA-310M | Display Colour Analyzer | 2014 | CA-410 |
CL-200 | Incident Color Meter | 2000 | CL-200A |
CS-1000(A/S/T) | Spectrophotometer | 1995 | CS-2000(A) |
T-1 | Illuminance Meter | 1979 | |
T-1H | Illuminance Meter | 1979 | |
T-1M | Illuminance Meter | 1979 | |
XY-1 | Chroma-Meter | 1980 | |
CL-100 | Chroma-Meter | 1982 | |
CL-200 | Chroma-Meter | 2000 | CL-200A |
nt 1 | Luminance-Meter | 1977 | |
nt 1/3 | Luminance-Meter | 1977 | |
DP-100 | Data Processor | 1985 'Servo-i Ventilator System – User's manual'. After any service intervention in the Servo-i, perform a 'Pre-use check' according to instructions in the 'Servo-i Ventilator System – User's manual'. Handling PC boards The PC boards contain components that are highly sensitive to static electricity. Those who come into contact with. Servo-u features an ergonomic design. The screen can be rotated through 360°, which means you can place the ventilator anywhere around the bed depending on clinical requirements. You can also mount Servo-u on a ceiling supply unit or shelf. The system is light and compact, making it highly suitable for intra-hospital transport. Simple to learn. A wealth of features and functionalities for treating adult, pediatric and neonatal patients all in one platform. SERVO-i® combines a high level of clinical performance for invasive, non-invasive or neurally controlled ventilation with outstanding mobility and cost efficiency. Maquet servo u ventilator pdf. Instructions for use Please carefully read the user’s manual Legal manufacturer Maquet Critical Care AB Other products See separate datasheets. Contact your local Getinge supplier for more information. The ventilator—General SERVO-U SERVO-U on mobile cart Base system weight Approximately 23 kg (50.7 lbs). Patient unit 15 kg (33.0 lbs). | -- |
DP-101 | Data Processor | 1985 | -- |
UM-1 | UV Radiometer Base unit | 1989 | -- |
UM-10 | UV Radiometer | 1986 | -- |
Model | Type | Year of introduction | Recommended Successor Model |
---|---|---|---|
CA-100 | CRT Color Analyzer | 1989 | |
CA-100Plus | CRT Color Analyzer | 2002 | CA-410 |
CA-110 | LCD Color Analyzer | 1991 | |
CA-120 | PJ Color Analyzer | 1999 | -- |
CA-210 | CRT Color Analyzer | 2002 | CA-410 |
CB-150 | CRT Focus Meter | 1996 | -- |
CB-250 | CRT Focus Meter | 1997 | -- |
CC-100 | CRT Convergence Meter | 1995 | -- |
CC-110 | CRT Convergence Meter | 1997 | -- |
CC-200 | CRT Conver. Meter | 1993 | -- Aug 26, 2018 Discover More. Where to Buy Our Sony Products are available to buy through retailers near you. DVD Player with USB / Included components may vary by country or region of purchase. PDFOperating Instructions (260 KB) Release Date:. https://goldel.netlify.app/sony-dvp-sr660p-user-manual-pdf.html. |
IA-1000M | CRT Image Analyzer Main Unit | 1998 | -- |
IA-1100M | CRT IMAGE ANALYZER | 2000 | -- |
IA-1200M | CRT IMAGE ANALYZER | 2000 | -- |
TVCA-II | TV Color Analyzer | 1981 |
The CL-500A is a lightweight, compact illuminance spectrophotometer used for the evaluation of high-class, next-generation lamps such as LED and EL illumination. It is the first handheld illuminance spectrophotometer to conform to both DIN and JIS standards. The CL-500A can measure illuminance, color temperature, CRI (Color Rendering Index), chromaticity, and spectral power distribution. Plus, the S/P ratio of scotopic illuminance and photopic illuminance can also be displayed.
The CL-500A'0019s convenient measurement functions include continuous measurement mode, display of the averaging of multiple measurements, delayed-measurement function, and the display of data at a specific wavelength. The spectral irradiance can be measured at 1-nm pitch from 360 to 780nm, so it can be used for measuring the color of light and photosynthetic photon flux density (PPFD). High speed measurement is possible using the Software Development kit (5 times/second).
The data management software CL-s10w, is included as a standard accessory. It includes a template for expressing the chromaticity variation of illumination light sources such as LEDs or OLEDs in terms of the MacAdam SDCM (Standard Deviation of Color Matching) step. This allows display of color differences that closely match visual judgment. The software is also equipped with an LED binning function and a spectral irradiance waveform display.
Features
- Portable, lightweight, compact and handheld
- Conforms to both DIN and JIS standards
- High-speed measurement possible using the software development kit
- Can be operated with USB bus power
- Measures and displays both the general color rendering index (Ra) and the special color rendering indexes (R1 to R15)
- Scotopic illuminance and the S/P ratio of scotopic illuminance can be measured with the instrument alone and with the included software
- Measurement functions: Continuous measurement mode, average of multiple measurements, delayed measurement and the display of data at specific wavelengths
- CS-S10w data management software included as a standard accessory
Specifications
Model | Illuminance Spectrophotometer CL-500A |
---|---|
Illuminance meter class | Conforms to requirements for Class AA of JIS C 1609-1: 2006 'illuminance meters Part 1: General measuring instruments'*1 Conforms to DIN5032 Part 7 Class B |
Spectral wavelength range | 360 to 780 nm |
Output wavelength pitch | 1 nm |
Spectral bandwidth | Approx. 10 nm (half bandwidth) |
Wavelength precision | +-0.3 nm (Median wavelengths of 435.8 nm, 546.1 nm, and 585.3 nm*2 as specified in JIS Z 8724)*3 |
Measuring range | 0.1 to 100,000 lx (chromaticity display requires 5 lx or more) |
Accuracy *4, 5 (Standard illuminants A) | Ev (Illuminance) : +-2%+-1 digit of displayed value xy: +-0.0015 (10 to 100,000 lx) xy: +-0.002 (5 to 10 lx) |
Repeatability (2 sigma;) (Standard illuminant A) | Ev: 0.5% + 1digit xy: .0005 (500 to 100,000 lx) xy: .001 (100 to 500 lx) xy: .002 (30 to 100 lx) xy: 0.004 (5 to 30 lx) |
Visible-region relative spectral response characteristics (f) | Within 1.5% of spectral luminous efficiency V ( λ) |
Cosine response (f2) | Ev: Within 3% |
Temperature drift (fT) | Ev: +-3% of displayed value; xy: +-0.003 |
Humidity drift (fH) | Ev: +-3% of displayed value; xy: +-0.003 |
Measurement time | Super Fast mode: Approx. 0.2 sec. (when connected to computer); Fast mode: Approx. 0.5 sec.; Slow mode: Approx. 2.5 sec.; Automatic exposure time setting (high accuracy) mode: Approx. 0.5 to 27 sec. |
Color indication modes | XYZ; X10Y10Z10; Evxy; Ev; Ev; Dominant wavelength, Excitation purity; Correlated color temperature, Delta;uv; General color-rendering index (Ra); Special color-rendering indexes (Ri (i=1~15)); Spectral graph; Peak wavelength; Delta(XYZ);Delta(X10Y10Z10);Delta (Evxy);Delta (Ev); Rank display; Scotopic illuminance; S/P ratio; Spectral irradiance |
Other functions | Data memory: 100 data; User calibration function (when connected to computer); Averaged measurements; Delayed Measurment; Continuous measurement; Auto power off function |
Display languages | English, Japanese, Chinese (Simplified) |
Interface | USB 2.0 |
Power source | Rechargeable internal lithium-ion battery (Operating time per charge: Approx. 6 hours when new); AC adapter; USB power bus |
Operating temperature/humidity range | -10 to 40°C, relative humidity of 85% or less (at 35°C) with no condensation |
Storage temperature/humidity rangen | -10 to 40° C, relative humidity 85% or less (at 35° C) with no condensation |
Dimensions (W x H x D) | 70 x 165 x 83 mm |
Weight | 350 g |
*1 For Section 7.6.3 Response Time, when measurement speed mode is set to FAST mode. | |
*2 For 585.3 nm, evaluation performed using substitute wavelength of 587.5 nm. | |
*3 Based on Konica Minolta test standards (change in temperature of 2 deg;C or less after zero calibration.) | |
*4 Automatic exposure time setting (high accuracy) mode |
Included Accessories
FD-A05 Soft Case
Buy Now >
Lens Cap with Strap
Buy Now >
Suggested Accessories
Konica Minolta Cl 200 User Manual Free
JCSS and Cal. Cert. Set A
Buy Now >
Konica Minolta Cl 200 User Manual Pdf
Test Report (Acceptance Angle)
Buy Now >