Konica Minolta Cl 200 User Manual

  1. Konica Minolta Cl 200 User Manual Free
  2. Konica Minolta Cl 200 User Manual Pdf

Not be removed or the receptor window is scratched, contact the nearest Konica Minolta authorized service facility. In cases of malfunction, do not disassemble the CL-200A or attempt to repair it yourself. Contact the nearest Konica Minolta-authorized service facility. How to Store. Konica Minolta TN-514K TN-514C TN-514 TN-514Y Bizhub C458 C558 C658 Toner Cartridge Set (Black Cyan Magenta Yellow, 4-Pack) in Retail Packaging. $200.00 $ 200. Illuminance Color Meters from Konica Minolta measure photometric brightness and also provide detailed color information for light readings. CL-500A Illuminance Spectrophotometer The CL-500A is a lightweight, compact illuminance spectrophotometer used for the evaluation of high-class, next-generation lamps such as LED and EL illumination. Konica Minolta Honored By The Cannata Report Earns Three Frank Awards Including Best Marketing Strategy, Best Production Print Manufacturer And Best Female Executive 2019.11.6 Konica Minolta Partners With The National Kidney Foundation For NYC Kidney Walk President and CEO Rick Taylor to Co-chair 18th Annual Event.

Konica minolta cl-200a Is Similar To: CA-210 Konica Minolta (40.4% similar) This device has a luminance measuring range starting at cd m2. This device can measure distances as short as 20 40mm making it ideal for compact systems. Konica Minolta Sensing enjoy an unparalleled reputation for the reliability and longevity of their instruments. However, continual development in component technology means that eventually it is not possible to continue to support and maintain older instruments.

Konica Minolta Sensing enjoy an unparalleled reputation for the reliability and longevity of their instruments. However, continual development in component technology means that eventually it is not possible to continue
to support and maintain older instruments.

Because of this Konica Minolta Sensing Inc. are announcing the discontinuation of technical support for calibration- and repair services for the following instrument models.

Minolta

The list below shows the items concerned as well as the recommended replacement model.

ModelTypeYear of introductionRecommended Successor Model
CM-3700dSpectrophotometer1994CM-3700A
CM-3600dSpectrophotometer1997CM-3600A
CM-3610dSpectrophotometer1998CM-3610A
CM-3500dSpectrophotometer1996CM-5
CM-3800dSpectro-Fluorimeter1998--

CM-1000

Box type Spectrophotometer

1987

CM-1000RH

Box type Spectrophotometer

1989

CM-2002

Portable Spectrophotometer

1991

CM-2022

Portable Spectrophotometer Kioti service manual free download 3054.

1992

CM-3200d

Box type Spectrophotometer

1995

CM-3300d

Spectrophotometer

1998

CM-503c

Portable Spectrophotometer

1994

CM-2500c
CM-25cG

CM-503d

Portable Spectrophotometer

1997

CM-503i

Portable Spectrophotometer

1993

CM-508c

Portable Spectrophotometer

1994

CM-2500c
CM-25cG

CM-508d

Portable Spectrophotometer

1993

CM-508i

Portable Spectrophotometer

1993

CM-525i

Portable Spectrophotometer

1994

CM-512m1

Portable Spectrophotometer

1994

CM-512m2

Portable Spectrophotometer

Shopsmith 5 manual download. 1997

CM-512m3Portable Spectrophotometer1997CM-M6

CR-15 (CECF-6)

Color Reader

1997

--

CECF-9

Color Reader

1997

--

CR-200

Chroma-Meter

1986

CR-200b

Chroma-Meter

1986

CR-210

Chroma-Meter

1986

CR-210b

Chroma-Meter

1986

CR-221

Chroma-Meter

1987

CM-2500c
CM-25cG

CR-231

Chroma-Meter

1990

CM-2500c
CM-25cG

CR-241

Chroma-Meter

1989

--

CR-300

Chroma-Meter

1990

CR-310

Chroma-Meter

1990

CR-321

Chroma-Meter

1991

CM-2500c
CM-25cG

CR-331

Chroma-Meter

1990

CM-2500c
CM-25cG

CR-331c

Chroma-Meter

1991

CM-2500c
CM-25cG

CR-354

Chroma-Meter Tri-View

1992

--

CT-100

Chroma-Meter

1985

CM-5
CR-5

CT-210

Chroma-Meter

1986

CM-5
CR-5

CT-310

Chroma-Meter

1991

CM-5
CR-5

CT-320

Chroma-Meter

1992

CM-5
CR-5

CF-1

Power Supply

1989

--

CF-101

Online Color Sensor

1989

--

CF-131

Online Color Sensor

1993

--

CF-1440

Online Color Sensor

1997

--

GM-060

Gloss Meter

1988

ModelTypeYear of
introduction
Recommended
Successor Model
CA-310Display Colour Analyzer2010CA-410
CA-310MDisplay Colour Analyzer2014CA-410
CL-200Incident Color Meter2000CL-200A
CS-1000(A/S/T)Spectrophotometer1995CS-2000(A)

T-1

Illuminance Meter

1979

T-1H

Illuminance Meter

1979

T-1M

Illuminance Meter

1979

XY-1

Chroma-Meter

1980

CL-100

Chroma-Meter

1982

CL-200Chroma-Meter2000CL-200A

nt 1

Luminance-Meter

1977

nt 1/3

Luminance-Meter

1977

DP-100

Data Processor

1985

'Servo-i Ventilator System – User's manual'. After any service intervention in the Servo-i, perform a 'Pre-use check' according to instructions in the 'Servo-i Ventilator System – User's manual'. Handling PC boards The PC boards contain components that are highly sensitive to static electricity. Those who come into contact with. Servo-u features an ergonomic design. The screen can be rotated through 360°, which means you can place the ventilator anywhere around the bed depending on clinical requirements. You can also mount Servo-u on a ceiling supply unit or shelf. The system is light and compact, making it highly suitable for intra-hospital transport. Simple to learn. A wealth of features and functionalities for treating adult, pediatric and neonatal patients all in one platform. SERVO-i® combines a high level of clinical performance for invasive, non-invasive or neurally controlled ventilation with outstanding mobility and cost efficiency. Maquet servo u ventilator pdf. Instructions for use Please carefully read the user’s manual Legal manufacturer Maquet Critical Care AB Other products See separate datasheets. Contact your local Getinge supplier for more information. The ventilator—General SERVO-U SERVO-U on mobile cart Base system weight Approximately 23 kg (50.7 lbs). Patient unit 15 kg (33.0 lbs).

--

DP-101

Data Processor

1985

--

UM-1

UV Radiometer Base unit

1989

--

UM-10

UV Radiometer

1986

--

ModelTypeYear of
introduction
Recommended
Successor Model

CA-100

CRT Color Analyzer

1989

CA-100PlusCRT Color Analyzer2002CA-410

CA-110

LCD Color Analyzer

1991

CA-120

PJ Color Analyzer

1999

--

CA-210CRT Color Analyzer2002CA-410

CB-150

CRT Focus Meter

1996

--

CB-250

CRT Focus Meter

1997

--

CC-100

CRT Convergence Meter

1995

--

CC-110

CRT Convergence Meter

1997

--

CC-200

CRT Conver. Meter

1993

--

Aug 26, 2018  Discover More. Where to Buy Our Sony Products are available to buy through retailers near you. DVD Player with USB / Included components may vary by country or region of purchase. PDFOperating Instructions (260 KB) Release Date:. https://goldel.netlify.app/sony-dvp-sr660p-user-manual-pdf.html.

IA-1000M

CRT Image Analyzer Main Unit

1998

--

IA-1100M

CRT IMAGE ANALYZER

2000

--

IA-1200M

CRT IMAGE ANALYZER

2000

--

TVCA-II

TV Color Analyzer

1981

The CL-500A is a lightweight, compact illuminance spectrophotometer used for the evaluation of high-class, next-generation lamps such as LED and EL illumination. It is the first handheld illuminance spectrophotometer to conform to both DIN and JIS standards. The CL-500A can measure illuminance, color temperature, CRI (Color Rendering Index), chromaticity, and spectral power distribution. Plus, the S/P ratio of scotopic illuminance and photopic illuminance can also be displayed.

The CL-500A'0019s convenient measurement functions include continuous measurement mode, display of the averaging of multiple measurements, delayed-measurement function, and the display of data at a specific wavelength. The spectral irradiance can be measured at 1-nm pitch from 360 to 780nm, so it can be used for measuring the color of light and photosynthetic photon flux density (PPFD). High speed measurement is possible using the Software Development kit (5 times/second).

The data management software CL-s10w, is included as a standard accessory. It includes a template for expressing the chromaticity variation of illumination light sources such as LEDs or OLEDs in terms of the MacAdam SDCM (Standard Deviation of Color Matching) step. This allows display of color differences that closely match visual judgment. The software is also equipped with an LED binning function and a spectral irradiance waveform display.


Features

  • Portable, lightweight, compact and handheld
  • Conforms to both DIN and JIS standards
  • High-speed measurement possible using the software development kit
  • Can be operated with USB bus power
  • Measures and displays both the general color rendering index (Ra) and the special color rendering indexes (R1 to R15)
  • Scotopic illuminance and the S/P ratio of scotopic illuminance can be measured with the instrument alone and with the included software
  • Measurement functions: Continuous measurement mode, average of multiple measurements, delayed measurement and the display of data at specific wavelengths
  • CS-S10w data management software included as a standard accessory
C364

Specifications

Konica minolta manual pdf
ModelIlluminance Spectrophotometer CL-500A
Illuminance meter classConforms to requirements for Class AA of JIS C 1609-1: 2006 'illuminance meters Part 1:
General measuring instruments'*1
Conforms to DIN5032 Part 7 Class B
Spectral wavelength range360 to 780 nm
Output wavelength pitch1 nm
Spectral bandwidthApprox. 10 nm (half bandwidth)
Wavelength precision+-0.3 nm (Median wavelengths of 435.8 nm, 546.1 nm, and 585.3 nm*2 as specified in JIS Z 8724)*3
Measuring range0.1 to 100,000 lx (chromaticity display requires 5 lx or more)
Accuracy *4, 5 (Standard illuminants A)Ev (Illuminance) : +-2%+-1 digit of displayed value
xy: +-0.0015 (10 to 100,000 lx)
xy: +-0.002 (5 to 10 lx)
Repeatability (2 sigma;) (Standard illuminant A)Ev: 0.5% + 1digit
xy: .0005 (500 to 100,000 lx) xy: .001 (100 to 500 lx)
xy: .002 (30 to 100 lx)
xy: 0.004 (5 to 30 lx)
Visible-region relative spectral response characteristics (f)Within 1.5% of spectral luminous efficiency V ( λ)
Cosine response (f2)Ev: Within 3%
Temperature drift (fT)Ev: +-3% of displayed value; xy: +-0.003
Humidity drift (fH)Ev: +-3% of displayed value; xy: +-0.003
Measurement timeSuper Fast mode: Approx. 0.2 sec. (when connected to computer);
Fast mode: Approx. 0.5 sec.;
Slow mode: Approx. 2.5 sec.;
Automatic exposure time setting (high accuracy) mode: Approx. 0.5 to 27 sec.
Color indication modesXYZ; X10Y10Z10; Evxy; Ev; Ev; Dominant wavelength, Excitation purity; Correlated color temperature, Delta;uv; General color-rendering index (Ra); Special color-rendering indexes (Ri (i=1~15)); Spectral graph; Peak wavelength; Delta(XYZ);Delta(X10Y10Z10);Delta (Evxy);Delta (Ev); Rank display; Scotopic illuminance; S/P ratio; Spectral irradiance
Other functionsData memory: 100 data; User calibration function (when connected to computer); Averaged measurements; Delayed Measurment; Continuous measurement; Auto power off function
Display languagesEnglish, Japanese, Chinese (Simplified)
InterfaceUSB 2.0
Power sourceRechargeable internal lithium-ion battery (Operating time per charge: Approx. 6 hours when new); AC adapter; USB power bus
Operating temperature/humidity range-10 to 40°C, relative humidity of 85% or less (at 35°C) with no condensation
Storage temperature/humidity rangen-10 to 40° C, relative humidity 85% or less (at 35° C) with no condensation
Dimensions (W x H x D)70 x 165 x 83 mm
Weight350 g
*1 For Section 7.6.3 Response Time, when measurement speed mode is set to FAST mode.
*2 For 585.3 nm, evaluation performed using substitute wavelength of 587.5 nm.
*3 Based on Konica Minolta test standards (change in temperature of 2 deg;C or less after zero calibration.)
*4 Automatic exposure time setting (high accuracy) mode

Included Accessories


FD-A05 Soft Case
Buy Now >

Lens Cap with Strap
Buy Now >

Suggested Accessories

Konica Minolta Cl 200 User Manual Free


JCSS and Cal. Cert. Set A
Buy Now >

Konica Minolta Cl 200 User Manual Pdf


Test Report (Acceptance Angle)
Buy Now >